Description: Requirements for Electrical Installations, Iet Wiring Regulations, Eighteenth Edition, Bs 7671:2018 by The Institution Of Engineering And Technology The IET Wiring Regulations is the national standard to which all domestic and industrial wiring must conform. The Eighteenth Edition is a major update to this title and contains extensive changes to many areas of BS 7671. FORMAT Paperback LANGUAGE English CONDITION Brand New Publisher Description The IET Wiring Regulations are of interest to all those concerned with the design, installation and maintenance of electric wiring in buildings. This includes electricians, electrical contractors, consultants, local authorities, surveyors and architects. This book will also be of interest to professional engineers, as well as students at university and further education colleges. The 18th Edition of the IET Wiring Regulations published in July 2018 and came into effect in January 2019. Changes from the previous edition include requirements concerning Surge Protection Devices, Arc Fault Detection Devices and the installation of electric vehicle charging equipment as well as many other areas. Table of Contents Introduction to BS 7671:2018 Part 1: Scope, object and fundamental principles Chapter 11: Scope Chapter 12: Object and effects Chapter 13: Fundamental principles Part 2: Definitions Part 3: Assessment of general characteristics Chapter 31: Purposes, supplies and structure Chapter 32: Classification of external influences Chapter 33: Compatibility Chapter 34: Maintainability Chapter 35: Safety services Chapter 36: Continuity of service Part 4: Protection for safety Chapter 41: Protection against electric shock Chapter 42: Protection against thermal effects Chapter 43: Protection against overcurrent Chapter 44: Protection against voltage disturbances and electromagnetic disturbances Chapter 46: Isolation and switching Part 5: Selection and erection of equipment Chapter 51: Common rules Chapter 52: Selection and erection of wiring systems Chapter 53: Protection, isolation, switching, control and monitoring Chapter 54: Earthing arrangements and protective conductors Chapter 55: Other equipment Chapter 56: Safety services Part 6: Inspection and testing Chapter 64: Initial verification Chapter 65: Periodic inspection and testing Part 7: Special installations or locations Section 700 General Section 701: Locations containing a bath or shower Section 702: Swimming pools and other basins Section 703: Rooms and cabins containing sauna heaters Section 704: Construction and demolition site installations Section 705: Agricultural and horticultural premises Section 706: Conducting locations with restricted movement Section 708: Electrical installations in caravan / camping parks and similar locations Section 709: Marinas and similar locations Section 710: Medical locations Section 711: Exhibitions, shows and stands Section 712: Solar photovoltaic (pv) power supply systems Section 714: Outdoor lighting installations Section 715: Extra-low voltage lighting installations Section 717: Mobile or transportable units Section 721: Electrical installations in caravans and motor caravans Section 722: Electric vehicle charging installations Section 729: Operating and maintenance gangways Section 730: Onshore units of electrical shore connections for inland navigation vessels Section 740: Temporary electrical installations for structures, amusement devices and booths at fairgrounds, amusement parks and circuses Section 753: Heating cables and embedded heating systems Appendices 1: British standards to which reference is made in this standard 2: Statutory regulations and associated memoranda 3: Time/current characteristics of overcurrent protective devices and RCDs 4: Current-carrying capacity and voltage drop for cables 5: Classification of external influences 6: Model forms for certification and reporting 7: Harmonized cable core colours 8: Current-carrying capacity and voltage drop for busbar trunking and powertrack systems 9: Definitions - multiple source, DC and other systems 10: Protection of conductors in parallel against overcurrent 11: Not used 12: Not used 13: Methods for measuring the insulation resistance/impedance of floors and walls to earth or to the protective conductor system 14: Determination of prospective fault current 15: Ring and radial final circuit arrangements, Regulation 433.1 16: Devices for protection against overvoltage 17: Energy efficiency Table of figures Table of tables Index y of service Part 4: Protection for safety Chapter 41: Protection against electric shock Chapter 42: Protection against thermal effects Chapter 43: Protection against overcurrent Chapter 44: Protection against voltage disturbances and electromagnetic disturbances Chapter 46: Isolation and switching Part 5: Selection and erection of equipment Chapter 51: Common rules Chapter 52: Selection and erection of wiring systems Chapter 53: Protection, isolation, switching, control and monitoring Chapter 54: Earthing arrangements and protective conductors Chapter 55: Other equipment Chapter 56: Safety services Part 6: Inspection and testing Chapter 64: Initial verification Chapter 65: Periodic inspection and testing Part 7: Special installations or locations Section 700 General Section 701: Locations containing a bath or shower Section 702: Swimming pools and other basins Section 703: Rooms and cabins containing sauna heaters Section 704: Construction and demolition site installations Section 705: Agricultural and horticultural premises Section 706: Conducting locations with restricted movement Section 708: Electrical installations in caravan / camping parks and similar locations Section 709: Marinas and similar locations Section 710: Medical locations Section 711: Exhibitions, shows and stands Section 712: Solar photovoltaic (pv) power supply systems Section 714: Outdoor lighting installations Section 715: Extra-low voltage lighting installations Section 717: Mobile or transportable units Section 721: Electrical installations in caravans and motor caravans Section 722: Electric vehicle charging installations Section 729: Operating and maintenance gangways Section 730: Onshore units of electrical shore connections for inland navigation vessels Section 740: Temporary electrical installations for structures, amusement devices and booths at fairgrounds, amusement parks and circuses Section 753: Heating cables and embedded heating systems Appendices 1: British standards to which reference is made in this standard 2: Statutory regulations and associated memoranda 3: Time/current characteristics of overcurrent protective devices and RCDs 4: Current-carrying capacity and voltage drop for cables 5: Classification of external influences 6: Model forms for certification and reporting 7: Harmonized cable core colours 8: Current-carrying capacity and voltage drop for busbar trunking and powertrack systems 9: Definitions - multiple source, DC and other systems 10: Protection of conductors in parallel against overcurrent 11: Not used 12: Not used 13: Methods for measuring the insulation resistance/impedance of floors and walls to earth or to the protective conductor system 14: Determination of prospective fault current 15: Ring and radial final circuit arrangements, Regulation 433.1 16: Devices for protection against overvoltage 17: Energy efficiency Table of figures Table of tables Index >Chapter 54: Earthing arrangements and protective conductors Chapter 55: Other equipment Chapter 56: Safety services Part 6: Inspection and testing Chapter 64: Initial verification Chapter 65: Periodic inspection and testing Part 7: Special installations or locations Section 700 General Section 701: Locations containing a bath or shower Section 702: Swimming pools and other basins Section 703: Rooms and cabins containing sauna heaters Section 704: Construction and demolition site installations Section 705: Agricultural and horticultural premises Section 706: Conducting locations with restricted movement Section 708: Electrical installations in caravan / camping parks and similar locations Section 709: Marinas and similar locations Section 710: Medical locations Section 711: Exhibitions, shows and stands Section 712: Solar photovoltaic (pv) power supply systems Section 714: Outdoor lighting installations Section 715: Extra-low voltage lighting installations Section 717: Mobile or transportable units Section 721: Electrical installations in caravans and motor caravans Section 722: Electric vehicle charging installations Section 729: Operating and maintenance gangways Section 730: Onshore units of electrical shore connections for inland navigation vessels Section 740: Temporary electrical installations for structures, amusement devices and booths at fairgrounds, amusement parks and circuses Section 753: Heating cables and embedded heating systems Appendices 1: British standards to which reference is made in this standard 2: Statutory regulations and associated memoranda 3: Time/current characteristics of overcurrent protective devices and RCDs 4: Current-carrying capacity and voltage drop for cables 5: Classification of external influences 6: Model forms for certification and reporting 7: Harmon Details ISBN1785611704 Author The Institution Of Engineering And Technology Publisher Institution Of Engineering And Technology Series Electrical Regulations Year 2018 ISBN-10 1785611704 ISBN-13 9781785611704 Format Paperback Pages 560 Publication Date 2018-07-02 Language English DEWEY 621.31924 Audience College/Higher Education UK Release Date 2018-07-02 Imprint Institution of Engineering and Technology Place of Publication Stevenage Country of Publication United Kingdom AU Release Date 2018-07-02 NZ Release Date 2018-07-02 Replaced by 9781839532184 We've got this At The Nile, if you're looking for it, we've got it. With fast shipping, low prices, friendly service and well over a million items - you're bound to find what you want, at a price you'll love! TheNile_Item_ID:161066322;
Price: 226.96 AUD
Location: Melbourne
End Time: 2024-11-19T05:10:29.000Z
Shipping Cost: 20.65 AUD
Product Images
Item Specifics
Restocking fee: No
Return shipping will be paid by: Buyer
Returns Accepted: Returns Accepted
Item must be returned within: 30 Days
ISBN-13: 9781785611704
Book Title: Requirements for Electrical Installations, Iet Wiring Regulations
Publisher: Institution of Engineering and Technology
Publication Year: 2018
Item Height: 297 mm
Number of Pages: 560 Pages
Language: English
Publication Name: Requirements for Electrical Installations, Iet Wiring Regulations, Eighteenth Edition, Bs 7671:2018
Type: Textbook
Author: The Institution of Engineering and Technology
Subject Area: Electrical Engineering
Item Width: 210 mm
Format: Paperback